Tenant fireplace safety, checked and written down per unit
Plan a building visit
Property address, number of fireplaces, wood or gas, and who arranges entry.
The safety items we look at in every unit
These are the things that can hurt a tenant. They lead every page of the record, ahead of wear and cosmetic notes.
- Carbon monoxide alarm present in the unit and within reach of the sleeping area.
- Flue open from the firebox to the top: no nest, no fallen tile, no heavy soot build-up.
- Damper opens fully; on gas log sets, a clamp holds it open so fumes cannot back up.
- Gas set lights cleanly with a steady blue base and no smell at the valve.
- Hearth and surround intact so a spark or ember cannot reach wood framing.
- Cap and spark screen in place at the top of the flue.
How a multi-unit visit runs
We work from your list of units with fireplaces and go door to door with whoever holds the keys or has given tenants notice. Each fireplace gets the same checks in the same order, so the records line up and a board or an owner can compare them. Roof items shared by several units, such as a stack with four flues, are recorded once and cross referenced on each unit page.
Where a unit fails a safety item, the page says so at the top in plain words and recommends whether the fireplace should be used until it is fixed. You get that flag in the report itself, not buried in a footnote.
Records that hold up later
The record is dated, names the unit, and has photos of the firebox, the damper and the top of the flue. If a tenant reports smoke or a smell months later, you can show what the fireplace looked like at the last check. Insurers and HOA boards ask for the same pages at renewal or after a claim.
State law calls for a working carbon monoxide alarm wherever a unit has a fuel burning appliance. We note whether one is present and where, so the manager can act; we do not supply or fit alarms.
Per fireplace pricing
The building total is the per fireplace figure times the number of fireplaces on your list. Sweeping is added only where a flue needs it.
- Visual safety check, each fireplace
- $56
- Camera follow up on a flagged flue
- $400
- Soot removal where a flue needs it
- from $430
A camera inspection is recommended for any unit whose visual check raises a question about the flue.
Manager and board questions
Do all units have to be done on one visit?
No, but it keeps the records consistent and avoids paying for repeat roof access. If tenants are hard to reach, we can split the building into two visits.
What if a tenant refuses entry?
We record the unit as not inspected and the reason. That page goes in the set so the file shows the attempt was made.
Do you inspect gas fireplaces in apartments?
Yes. Gas sets get the pilot and burner checks, the damper clamp check and a look at the venting. A sealed direct vent unit gets a check of its glass, gasket and outside termination.
Can the HOA board get the full set?
Yes. The client names who receives the records. Boards often take the full set and owners take their own unit page.
Will the record tell me which repairs are urgent?
Each unit page sorts findings into use with care, repair before next use, and note for later. Repair prices come separately so you can get other bids.
Get a dated fireplace record for every unit
Send the property address and your fireplace count through the contact page, say whether they burn wood or gas, and we return a per fireplace total and a visit plan.